- Mains supply (DC)
- 24 V-Logic supply
- Parameterization and diagnosis
- 6 digital inputs and 4 digital outputs
- Safety Intergrated: Restart lock to achieve category 4 according to EN 13849-1:2008-12, EN 62061:2008-04 and EN 61508:2002-11; Safety level SIL 3
- Encoder inputs (Puls-direction signals)
- Encoder outputs (measuring system simulation)
- Analog reference value interfaces: +/-10 V
- Resolver inputs
- Thermal contacts
- Universal motor encoder interface: Resolver, encoder / linear scale(TTL or SinCos), EnDat, Hiperface, SSI, Hall effect sensor, linearer Hall sensor, magnetoresistive sensor
- SERVOLINK 4 via optical fi ber connector
- 2 x Motor connection
The oscilloscope function allows optimization of the axes in the machine without additional measuring equipment. That way for example overshoots during positioning can be eliminated or resonance frequencies in the mechanical elements can be reduced.
The clear design of the software allows intuitive parameterization via graphics and block diagrams. The „Parameter-Wizard“ assists the user step-by-step through the system configuration and allows intuitive setup of the device via help messages and comments.
SD2 Multi-Axes Concept
One-channel Devises
325 V Mains supply (AC)
| Ir: 10 A |
Ip: 14 A |
410 x 70 x 225 mm |
| Ir: 14 A |
Ip: 28 A |
410 x 70 x 225 mm |
| Ir: 25 A |
Ip: 56 A |
410 x 70 x 225 mm |
680 V Mains supply (AC)
| Ir: 10 A |
Ip: 14 A |
410 x 70 x 225 mm |
| Ir: 14 A |
Ip: 28 A |
410 x 70 x 225 mm |
| Ir: 14 A |
Ip: 56 A |
410 x 70 x 225 mm |
| Ir: 35 A |
Ip: 113 A |
410 x 130 x 225 mm |
Two-channel Devices
325 V Mains supply (AC)
| Ir: 10 A + 10 A |
Ip: 14 A + 14 A |
410 x 70 x 225 mm |
| Ir: 10 A + 10 A |
Ip: 28 A + 28 A |
410 x 70 x 225 mm |
| Ir: 10 A + 20 A |
Ip: 28 A + 56 A |
410 x 100 x 225 mm |
| Ir: 10 A + 20 A |
Ip: 28 A + 85 A |
410 x 100 x 225 mm |
680 V Mains supply (AC)
| Ir: 7 A + 7 A |
Ip: 14 A + 14 A |
410 x 70 x 225 mm |
| Ir: 7 A + 7 A |
Ip: 28 A + 28 A |
410 x 70 x 225 mm |
| Ir: 7 A + 17 A |
Ip: 28 A + 56 A |
410 x 100 x 225 mm |
Ir = rated current, IP = peak current.
Stated currents are rms values.
Voltage limits at 325 V: 325 V -33% / +10%
Voltage limits at 680 V: 680 V -33% / +10%
The device dimensions are defi ned as height x width x depth, related to the mounting dimensions.
Power Supply PS2
110, 230, 400 and 480 V Mains supply (AC)
| Pr: 22 kW |
Pp: 45kW |
410 x 70 x 225 mm |
Pr = rated power, PP = peak performance.
The performance of the device is related to a 400 V mains supply. For different mains supply voltages the performance changes correspondingly.
The device dimensions are defi ned as height x width x depth, related to the mounting dimensions.
SD2 Compact Device
One-channel Devices with Integrated Power Supply
230 V Mains supply (AC)
| Ir: 14 A |
Ip: 56 A |
410 x 100 x 225 mm |
480 V Mains supply (AC)
| Ir: 14 A |
Ip: 56 A |
410 x 100 x 225 mm |
Two-channel Devices with Integrated Power Supply
230 V Mains supply (AC)
| IN: 11 A + 11 A |
IS: 14 A + 14 A |
410 x 100 x 225 mm |
| IN: 11 A + 11 A |
IS: 42 A + 42 A |
410 x 100 x 225 mm |
480 V Mains supply (AC)
| Ir: 7 A + 7 A |
Ip: 14 A + 14 A |
410 x 100 x 225 mm |
| Ir: 7 A + 7 A |
Ip: 42 A + 42 A |
410 x 100 x 225 mm |
Ir = rated current, Ip = peak current.
Stated currents are rms values.
Voltage limits at 230 V: 230 V -33% / +10%, related to the input voltage.
Voltage limits at 480 V: 480 V -33% / +10%, related to the input voltage.
The device dimensions are defi ned as height x width x depth, related to the mounting dimensions.