- External break resistor
- Main supply
- Digital I/Os
- LED status display
- RS232/485
- Incremental output
- 2 analog inputs and 2 analog outputs
- Transducer
- Motor feedback
- Motor connection
- Bus system
Servo Amplifier 36.05 with integrated Mains Filter and Ballast Circuit
| Type |
10/20 |
10/40 |
10/60 |
7/20 |
7/40 |
7/60 |
Mains connection
|
1 or 3 phases, 230 vAC |
3 phases, 400 VAC |
| Rated current [A] |
10 |
10 |
10 |
7 |
7 |
7 |
| Peak current [A]1 |
20 |
40 |
60 |
20 |
40 |
60 |
Internalballast resistor [W]
|
10 (externally expandable) |
| Dimensions W x H x D [mm]2 |
65 x 318 x 173 |
Additionally with Restart Lock3
| Type |
30/60 |
40/100 |
20/40 |
20/80 |
| Mains connection |
3 phases, 230 VAC |
3 phases, 400 VAC |
| Rated current [A] |
30 |
40 |
20 |
20 |
| Peak current [A]1 |
60 |
100 |
40 |
80 |
| Internalballast resistor [W] |
100 (externally expandable) |
| Dimensions W x H x D [mm]2 |
105 x 310 x 276 |
Rated and peak currents are sine crest values. Specifications apply for 20° C and 8 kHz PWM of output stage.
1 The maximum values are sustainable for up to 5 seconds.
2 Total Height, depth without plug connectors.
3 The currently effective safety category 4 can be reached by the restart
lock integrated in the devices with 20 A rated current or more.
Errors and omissions excepted.